Prime:750KVA(600KW )Standby:825KVA(660KW)

* Composed of Cummins,Deutz,SDEC,Perkins diesel engine and Stamford or Kusing, Marathon, Leroy somer alternator;

*24V DC start motor and storage battery;

*Brushless, Self-excited, IP23, insulation class H alternator;

*50℃ radiator as standard;

*Digitalstart panel control system as standard, digital auto-start panel is optional;

* 8-hour operation base tank;

*Optional open type or silent type;

*All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load , 110% load and all protection function (overspeed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)

Add to wishlist Add to compare

Description

RATING DEFINTION

PRIME POWER

Prime Power is available for an unlimited number of annual operating hours in variable load applications,in accordance with ISO8528-1

STAND BY POWER

The Standby Power is applicable for supplying emergency power for the duration of utility power interruption.No overload,utility parallel or negotiated outage operation capacity is available at this rating

TECHANICAL DATA
Generator set Genset Model CK36000 DK36000 PK36000 SK36000
Engine Brand Cummins Deutz Perkins SDEC
Engine Model KTA38-G2 HC12V132ZL-LAG1A 4006-23TAG2 SC33W990D2
Alternator Moedel S354G600E10
Controller Comap/Deep sea Kusing 6132
Switch CHNT 1250A
Internal protection IP22
Rate current(A) 1080
Specific Fuel Consumption(G/KW.H)@100% Load 198 197 209 205
Engine Model KTA38-G2 HC12V132ZL-LAG1A 4006-23TAG2 SC33W990D2
NO. of Cylinder 12 12 6 12
Cylinder Type V V V V
RPM 1500
Bore (mm) 159 132 160 180
Stroke(mm) 159 145  190 215
Speed Governor Electronic Electronic Electronic Electronic
Start system(VDC) 24 24 24 24
Lub Oil Specification CF/ 15W40 CF/15W40 CF/15W40 CF/15W40
Displacement(Ltrs) 37.8 23.8 22.9 32.8
Lub Oil Sump Capacity(Ltrs) 135 54 113 75-100
Coolant Capacity(Ltrs) 118(only engine) 30(only engine) 105(only engine) 56
Air inspiration Turbocharged Turbocharged Turbocharged Turbocharged
Alternator Phase 3
Brand Kusing
Model S354G600E10
3 Phase Voltage(1 Phase) Volts 380-415(220-240)
RPM/Frequency 1500rpm/50hz
Power Factor(%) 0.8(lagging)
Voltage Tolerance(+/- %) 1
Insulation Class H
Weight Open (KG) 5830 5830 5225 7070
Silent(KG) 6900 6900 6325 N/A
Size OPen(L*W*H)mm 4400*2010*2450 4020*1710*2250 4020*1710*2250 4362*1570*2135
Silent(L*W*H)mm 20 FT CONTAINER 20 FT CONTAINER 20 FT CONTAINER 20 FT CONTAINER
Noise(DBA) Open NA NA NA NA
Noise( 7M at the Genset) 80 80 80 80
Fuel Tank Capacity SUPPORT TO RUN 8 TO 10 HOURS

OPEN: